Modbus gateways with integrated Ethernet cascading

Advantech’s modbus gateways, the EKI-1221D and EKI-1222D, feature built-in Ethernet switches and provide transparent connectivity between Modbus serial devices and Ethernet-based Modbus/TCP equipment.

02/04/2011


Advantech Industrial Automation Group introduces two new modbus gateways with built-in Ethernet switches, the EKI-1221D and EKI-1222D. They both provide transparent connectivity between Modbus (ASCII, RTU) serial devices and Ethernet based Modbus/TCP equipment. They are able to fulfill flexible installation and web browser configuration requirements for remote monitoring applications.

They have built-in Ethernet switches for cascading/daisy-chain connectivity that offers flexible cabling. Cascading connections support Ethernet auto-bypass to prevent accidental power failure in the event one of the Modbus Gateway’s unexpectedly shuts down. They come with Windows utilities and web-based configuration, providing easier ways to set up. One port can be used to connect to the network, while the other can be used to connect to an Ethernet device or another EKI-1221D/1222D. For instance, one Ethernet port connects to an HMI, while another Ethernet port can connect to a PAC, allowing these devices to easily communicate. This provides a simple and cost-effective way to add remote management and data accessibility to thousand of devices that can’t connect to a network.

They provide 921k baud speeds and are designed to fulfill any master/slave relationship. Moreover, they support 16 TCP masters, 16 TCP slaves, and each serial port supports up to 31 RTU/ASCII slave devices.

They have built-in dual power inputs (12~48 Vdc) with one power fail relay output to detect power operation status and ensure reliable operation. They are built with thin DIN-rail mount form factors, IP30 metal housings, and Class I Division 2 certification for hazardous environment requirement.

www.advantech.com/ea

Advantech Corporation, Industrial Automation Group

- Edited by Amanda McLeman, Control Engineering, www.controleng.com

Advantech Corporation is a CSIA member as of 2/26/2015



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me