Mobile showroom demonstrates motion control solutions

Mitsubishi Electric Automation's Solutions in Motion is a mobile showroom that has interactive demonstration pods as well as an industrial, bottling-line demonstrating new products.

10/23/2012


Mitsubishi Electric Automation's Solutions in Motion is a mobile showroom that has interactive demonstration pods as well as an industrial, bottling-line demonstrating new products. Courtesy: Mitsubishi ElectricMitsubishi Electric Automation Inc. has a mobile showroom out on tour, taking motion control solutions directly to customers. The 53-ft long Solutions in Motion showroom has been appearing at tradeshows, open houses, training seminars and other events across North America.

Solutions In Motion has dual expandable walls, creating a space of more than 510 square-feet that can comfortably accommodate 25 people. It also has a 50- x 20-foot canopy for outdoor events.

Interactive demonstration pods in the Solutions Gallery with 32-in. high-definition video monitors display Mitsubishi Electric PLC products, servos, variable frequency drives (VFDs), human-machine interfaces (HMIs), and networks in a wide range of manufacturing applications. Overhead sound domes produce crisp, clear audio in a small area so guests can watch demonstrations without hearing sound from others.

Mitsubishi Electric Automation's Solutions in Motion is a mobile showroom that has interactive demonstration pods as well as an industrial, bottling-line demonstrating new products. Courtesy: Mitsubishi ElectricThe next section of the showroom is an industrial, bottling-line demonstration with exposed overhead conduit, compressed-air plumbing and duct work. Shown in action are a Mitsubishi Electric RH3 ceiling mount SCARA robot; a gear mesh device featuring MR-J3 rotary and linear servos; and vibration suppression equipment. Opposite that are Mitsubishi Electric’s e-F@ctory and connectivity solutions; and an F700 fan and pump controller packaged solution.

Mitsubishi Electric’s EnergyPaq energy monitoring system is on display at the front of the trailer. Voltage, current, power factor and total power consumption for eight circuits, including incoming power, HVAC, an air compressor and all of the demonstration pods are monitored and recorded. Energy data are stored in the cloud and accessible via the Internet.

Nearly all hardware is connected by an onboard wireless LAN with 3G/4G cellular broadband access for remote monitoring, analysis and upgrading. This also provides a hotspot for Internet access.

Mitsubishi Electric Automation Inc.

www.meau.com 

- Edited by CFE Media, Control Engineering, Plant Engineering



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me