Mini controller has IO-Link master, uses CoDeSys V3 software

Product Exclusive: Festo’s compact mechatronic controller CECC is the first mini controller with IO-Link master and CoDeSys V3 programming software, the company said. It reduces installation time, simplifies programming, and enables fast and cost-effective control of sensors and actuators.

11/12/2012


The compact Festo mechatronic controller CECC reduces installation time, simplifies programming, and is the first mini control system with IO-Link master and CoDeSys V3. Courtesy: FestoThe compact mechatronic controller CECC is the first mini controller with IO-Link master and CoDeSys V3 software for programming. It reduces installation times, simplifies programming, and enables fast and cost-effective control of sensors and actuators. The mechatronic controller CECC is the answer to small-scale automation applications with limited I/O connections. Despite modest dimensions, the CECC’s variety of interfaces allows it to handle different electric and pneumatic automation tasks. The mini controller also can serve as a CANopen master and interface and can be easily and reliably integrated into higher-level systems such as Profinet, EtherNet/IP, and Modbus TCP.

Fast diagnostics

major advantage of the CECC is its IO-Link master with four channels.

Festo offers ready-to-install valve terminals for the IO-Link interface. More sensors and actuators will be added to the range for this type of connection in the coming months. Third-party devices that conform to the IO-Link standard (IEC 61131-9) can, of course, also be actuated.

Easy installation

Parameterization of the I/O point can be done centrally during commissioning, without going to the installation site. The easy-to-operate configuration tool for IO-Link masters in CoDeSys V3 programming software speeds up commissioning of sensors and actuators, and the nominal/actual comparisons ensure operational reliability.

The integrated interface of the CECC is another step toward long-term simplification of data handling. It enables recipes and projects to be loaded, diagnostic and quality data to be recorded, and enables condition monitoring USB.

CANopen for automation

The integrated CANopen master of the mechatronic controller CECC enables actuation of all electric drives and valve terminals from Festo. The fieldbus master can be used as a further open interface for additional functions.

www.festo.com/us 

Festo

Online only

- Edited by Mark T. Hoske, content manager, CFE Media, Control Engineering and Plant Engineering, mhoske@cfemedia.com. 

Festo is a global manufacturer of pneumatic and electromechanical systems, components, and controls for process control and factory automation solutions, with more than 55 national headquarters serving more than 180 countries. With 40 years of innovation in the United States and more than 80 years globally, Festo continuously elevates the state of manufacturing with innovations and optimized motion control solutions that deliver higher performing, more profitable automated manufacturing, and processing equipment. Festo said, “Our dedication to the advancement of automation extends beyond technology to the education of current and future automation and robotic designers with simulation tools, teaching programs, and on-site services.” 

For more products, see

www.controleng.com/products



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me