Micro PLCs have embedded motion capabilities

Allen-Bradley Micro850 and Micro830 PLCs by Rockwell Automation have motion capabilities for up to three axes of motion and have embedded Ethernet ports for HMIs.

11/02/2012


The Micro850 and Micro830 PLCs by Rockwell Automation have motion capabilities for up to three axes of motion and have embedded Ethernet ports for HMIs (Pictured: Micro850). Courtesy: Rockwell AutomationRockwell Automation's Allen-Bradley Micro850 and enhanced Micro830 PLCs feature embedded motion capabilities for up to three axes of motion, allowing them to support a wide range of applications.

The Micro850 micro PLC is equipped with the same form factor, plug-in support, instruction/data size and motion capabilities as the 24-pt and 48-pt Micro830 controllers, but with the added capabilities of Ethernet and expansion I/O. The Micro850 controller specifically targets the needs of OEMs and excels at stand-alone machine applications.

The Micro850 controller has an embedded Ethernet port for higher performance connectivity to human-machine interfaces (HMIs). The EtherNet/IP protocol with CIP Symbolic support is used for simplified Allen-Bradley PanelView Component HMI connectivity. Tags created while configuring the HMI screens can easily reference the variable names in the Allen-Bradley Micro800 program.

I/O flexibility in the Micro850 PLC is one of the keys to successfully minimizing the cost of a machine. With support for up to five plug-ins, OEMs can customize the functionality of the controller with additional I/O, special functions, and serial ports without increasing the size of the controller. If more I/O or higher-performance analog I/O is required, the Micro850 controller supports up to four 2085 expansion I/O modules, including high-density digital I/O and high-accuracy analog I/O, for a total of 132 digital I/O points.

The enhanced Micro830 (via a firmware and software upgrade) and Micro850 controllers support up to three motion axes using pulse output to stepper or servo drives. OEMs can use intuitive motion function blocks, including Home, Move Velocity, Move Absolute, and Move Relative to make single-axis moves easy. For applications where precise positioning is required at high speeds, the Touch Probe function block has special hardware to achieve exact-position registration.

Rockwell Automation

www.rockwellautomation.com 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me