Medium-voltage transfer, bypass/isolation switches

Russelectric's medium-voltage bypass/isolation switches meet or exceed IEEE, NEMA, and ANSI standards and provide the functions of an automatic transfer switch.

11/26/2012


Russelectric's medium-voltage bypass/isolation switches meet or exceed IEEE, NEMA, and ANSI standards and provide the functions of an automatic transfer switch. Courtesy: RusselectricRusselectric’s medium-voltage (5 to 15 kV) circuit breaker-type transfer switches and bypass/isolation switches are tested, listed, and labeled under UL 1008A, making them suitable for use in legally required emergency power systems. These switches transfer electrical loads between normal and emergency power sources through the carefully controlled opening and closing of circuit breakers and may be configured for open- or closed-transition transfer. All switch functions are controlled by Russelectric’s RPTCS programmable microprocessor-based control system. All medium-voltage circuit breaker-type transfer switches meet or exceed stringent IEEE, NEMA, and ANSI standards. They provide all the functions of an automatic transfer switch plus the ability to bypass power from live source to load in the event the transfer switch becomes disabled. In addition, they are designed to allow isolation and de-energization of the automatic transfer breakers for maintenance, testing, and repair.  

Russelectric

www.russelectric.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me