Medium-voltage switchgear

Premset incorporates a Shield Solid Insulation System (2SIS) to enhance robustness, protection, and flexibility of medium-voltage switchgear.

04/13/2017


Schneider Electric PremsetPremset incorporates a Shield Solid Insulation System (2SIS) to enhance robustness, protection, and flexibility of medium-voltage switchgear. The 2SIS system encases every current-carrying conductor in dielectric epoxy and shields that epoxy with a grounded conductor to offer unprecedented safety, efficiency, and ease of use. Premset minimizes the risk of internal arc flash and prevents phase-to-phase faults by ground-shielding each individual phase. The circuit breaker and isolation switch are positive-indicated and interlocked to prevent access to live compartments. Maintenance is reduced due to better environmental protection for the current-carrying portions and complete encasement of the circuit breaker and isolation switch.

Schneider Electric, www.schneider-electric.us

This product is a Finalist in the Consulting-Specifying Engineer 2017 Product of the Year program. View more Finalists and cast your vote at www.csemag.com/votepoy (voting closes June 30, 2017).



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me