Mechatronics: You can’t just say a system is reliable

Here's why understanding the physics of failure and having a systems approach are essential to modern engineering. As we become more dependent on complex mechatronic systems, it is insufficient to understand just how they work; we must also understand how they fail. Fault-tolerant system design has become ...

01/01/2011


“A man’s got to know his limitations.” This is one of the more memorable lines delivered by Clint Eastwood in the movie “Magnum Force” and it possesses great wisdom. But how does this relate to engineering system reliability?

What do we mean when we say that a person is reliable? Is it possible to say that a person is reliable all the time or just sometimes, in all circumstances or in just some circumstances? The same questions need to be applied to an engineering system design because reliability cannot be an after-thought.

As we become more dependent on complex mechatronic systems, it is not sufficient to understand just how they work; we must also understand how they fail. Fault-tolerant system design, not just fault-tolerant component or subsystem design, has become paramount. Reliability is the probability that an item performs a required function under stated conditions for a stated period of time. So an engineer needs to define the functions a system must perform, the boundary conditions under which the system will operate and the time duration during which reliability is required.

To better understand reliability, I spoke with Tim Kerrigan, fluid power consulting engineer at Milwaukee School of Engineering’s Fluid Power Institute, where he works to ensure industrial and government systems are designed for reliability.

A physics-of-failure approach to reliability is consistent with the model-based approach of modern mechatronic system design. It uses modeling and analysis to design reliability into a system, perform reliability assessments and focus reliability tests where they will be most effective. The approach involves understanding and modeling the potential failure mechanisms (e.g., fatigue, wear, and temperature), the failure sites and the failure modes (the activation of the failure mechanisms).   The failure modes of a mechatronic system include those of mechanical, electrical, computer and control subsystems, i.e., hardware and software failures. A physics-of-failure approach can improve reliability, reduce the time to field systems, reduce testing and costs, and increase customer satisfaction.

As mechatronic systems become more complex, the interactions among the subsystems — mechanical, electrical, computer and control — become more difficult to manage and the overall system reliability is impacted by this integration. Therefore, an assessment of overall system reliability must have an adequate margin for safety. A useful analogy here is the feedback control system. It provides great benefits, but feedback control systems can become unstable if there is an imbalance between strength of corrective action (gain) and system dynamic lags (phase lags). Model uncertainty is quantified by assuming that either gain changes or phase changes occur and the tolerances of gain or phase uncertainty are the stability margins, gain margin and phase margin. Real systems must have adequate stability margins. Real systems must also have adequate reliability margins.

Mechatronics can enhance the reliability and fault-tolerance of a system with prognostics, diagnostics and built-in test capabilities. The additional sensors and control elements must be very reliable and do add additional cost. But the long-term cost of unreliability is huge compared to the initial design cost of reliability. In addition, designing for reliability enhances energy efficiency and sustainability. Reliability and fault-tolerance is a competitive advantage in the commercial market and an absolute requirement in the health care, military and transportation sectors.

Kevin C. Craig, Ph.D., Robert C. Greenheck Chair in Engineering Design and Professor of Mechanical Engineering, College of Engineering, Marquette University.

Visit the Mechatronics Zone for the latest mechatronics news, trends, technologies and applications.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me