Manufacturer focus: Designing labs, research buildings

05/28/2013


CSE: Provide details about a recent lab project in which your company’s controls were specified. What unusual problems did these controls solve?

Schneider Electric: Schneider Electric recently completed energy upgrades at 13 buildings at North Carolina State University (NCSU) through an energy saving performance contract. One of those buildings was a chemistry laboratory, Dabney Hall. One hundred eleven fume hoods were converted from constant volume to variable volume and linked to a central building automation system (BAS). NCSU expects the total energy savings to exceed the cost of the performance contract. With an annual utility bill of more than $30 million, every bit of energy savings helps. For example, the university expects improvements in Dabney Hall’s research labs to yield 20% in energy savings for the entire project.

CSE: What types of integrated systems have clients requested recently? Describe the control systems, and how they were integrated?

Schneider Electric: On current Biosafety Level 4 (BSL-4) projects, it has been clear that our clients need better integration with the hardware and software of the specialty door systems. Almost everything about these projects is restricted, but better sub-system integration is a key area to achieving safety, security, and reliability. The two major door systems in use at BSL-4 are submarine type doors with turning wheels and also doors with pressurized bladders that inflate and deflate. 

CSE: What renewable electrical system projects have you recently provided products for? Describe the electrical/power systems, renewable energy issues, etc. 

Schneider Electric: I had the privilege of being on the authoring committee when Labs21 put together its EPC criteria for labs. Both that standard and the U.S. Green Building Council LEED rating system put an increasing emphasis on providing greater and greater percentages of renewable energy to the lab building. The main lesson learned in this area is that first you aggressively save energy with conservation. This makes your job of providing greater percentages of the building's power through renewable energy more cost effective. 

CSE: Labs21 is working to make labs and research facilities more sustainable. What’s your experience with electrical/power projects that use Labs21 as a guide? 

Schneider Electric: Schneider Electric has been very active with Labs21 for more than 10 years as members, speakers, trainers, sponsors, and co-authors of papers and best practices. The current guidance from Labs21 on reducing "vampire" loads and accurately predicting plug loads for lab buildings has helped improve some of our current projects. 

CSE: What standby or back-up power systems are engineers and their clients requesting? Describe a recent project. 

Schneider Electric: The emphasis at Schneider Electric for back-up power systems for labs has been adding automation specifically for operating the emergency generators. This software suite can diagnose and predict future faults for maintenance before a shut-down occurs. The emergency generator is the one piece of equipment which is never allowed to fail.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me