Managing the complexities of natatoriums—part two

RTM Principal Doug Brewer shares his expertise on natatoriums, frequently referred to as indoor swimming pools.

05/20/2016


RTM Principal Doug Brewer shares his expertise on natatoriums, frequently referred to as indoor swimming pools. Courtesy: RTMRounding out a two-part series, RTM Principal Doug Brewer shares his expertise on natatoriums, frequently referred to as indoor swimming pools. In the first post, Brewer shared the complexities of natatoriums and outlined the importance of preventing condensation and achieving desirable indoor air quality. In the second installment, Brewer highlights the importance of creating optimum temperatures, equally vital for a successful facility.

Creating optimum temperatures

Temperature and humidity go hand-in-hand, playing a critical role in human comfort. It is essential that both are controlled and stable. The space temperature in a natatorium is unique to each project, but typically ranges between 75 and 85°F. Optimum relative humidity levels range between 40 and 60%. While 40% is certainly an acceptable indoor relative humidity level, most indoor pools do not operate lower than 50% rH due to significantly increased utility costs; increased pool-water evaporation rate resulting in more make-up water and water treatment; and swimmers leaving the water feeling chilly at lower humidity levels due to evaporation off their bodies.

While the space temperature should be dictated by the owner based on what satisfies the users, it is important to understand the resulting energy consumption. For example, at the same water temperature, a pool in a room at 78ºF and 50% rH will evaporate almost 35% more than that same pool in an 85ºF room at 50% rH. Every pound of moisture evaporated to the space is a load to be dehumidified, and it also represents heat lost by the pool water. Pool-water evaporation losses account for 90% of a pool's annual water heating cost. Every pound of moisture evaporated represents approximately 1,000 Btus of heat.

While each natatorium will need to accommodate specific design requirements stipulated by the owner, preventing condensation, achieving desirable indoor air quality, and creating optimum temperatures play an imperative role when providing a safe, healthy, comfortable, and energy-efficient pool environment.

-This article originally appeared on RTM. RTM is a CFE Media content partner.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me