Maisotsenko: A New Thermodynamic Cycle Offers Options in HVAC

12/20/2004


Last year, Arvada, Colo.-based Idalex Technologies, a research and development company, announced the discovery of a new thermodynamic cycle that captures significant amounts of energy from the atmosphere.

The Maisotsenko Cycle takes it name from one of Idalex Technologies' founders, Dr. Valeriy Maisotsenko, who has been researching this phenomenon for 40 years. The Maisotsenko Cycle captures energy from the atmosphere using the latent heat of evaporation through a unique heat and mass exchanger. Using one apparatus, the exchanger can cool any fluid to within a few degrees of the dew point temperature of ambient air. In addition, no moisture is added to the cooled fluid. Previously, it was thought that this was thermodynamically impossible.

This new cycle, which works both above and below atmospheric temperature and pressure, can dramatically improve any process that needs fluid cooling and/or saturated air. Applications include combustion and steam cycles, comfort cooling, cooling towers and fuel cells. The Maisotsenko combustion turbine cycle (MCTC) is said to produce power with fuel efficiencies above 60% without a bottoming cycle steam turbine. The MCTC is similar to the humid air turbine (HAT) cycle, but it uses far less equipment with much higher heat transfer rates and less pressure drop. Other benefits of the MCTC include lower NOx emissions and greatly reduced equipment costs compared to any other power cycle.

With the MCTC, the amount of superheating or humidifying is easily controlled and changed during operation, allowing added power or greater efficiency. The equipment uses existing shell and tube heat exchanger technologies, built in a new configuration.

Yuba Heat Transfer, a Division of Connell LP, has calculated and designed the heat and mass transfer equipment for the Maisotsenko Compressed Air Saturator/Turbine Exhaust Cooler. Idalex used the Maisotsenko Cooling Cycle to create a heat and mass exchanger for comfort cooling, which is called the Coolerado Cooler. The Coolerado Cooler has a Seasonal Energy Efficiency Rating (SEER) of 40, more than tripling existing commercial cooling system efficiencies. A government-testing agency has verified the Coolerado Cooler's efficiency and near dew point delivery of cool air.

For more information go to www.idalextechnologies.com .





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me