Machine Safety: 12 hazards of unused machinery

Look at the 5 levels of hazard mitigation to help determine risk of a machine no longer in use. Consider the following 12 hazards of end-of-lifecyle machines. An unused machine is not necessarily safe.

11/09/2014


The safety lifecycle of machinery has received significant attention over the past 10 years, especially how to perform safety mitigation during the design stage of a machine by applying the five levels of hazard mitigation. But at the tail end of the lifecycle, is a machine no longer in use considered safe? Machines at their end of lifecycle are often retired, decommissioned, or simply mothballed in place. 

5 levels of hazard mitigation

Even though a machine may no longer be active in the production process, this does not mean that the machine has been rendered hazard-free according to the five levels of hazard mitigation:

1) Eliminate the hazard - design it out

2) Isolate the hazard with hard guarding

3) Add additional engineering, guards, devices, or layers of safety

4) Implement administrative controls such as training, signage, assessments, etc.

5) Use personal protective equipment (PPE) such as goggles, gloves, outer clothing, shields, etc.

12 hazards to consider for a machine no longer in use

If a risk assessment were to be completed on a decommissioned machine, here are a few examples of potential residual hazards:

  1. Live electrical connections
  2. Compressed gases or fluids
  3. Charged tie rods
  4. Compressed springs
  5. Gravity
  6. Hazardous materials
  7. Rust
  8. Flammable or combustible material
  9. Abandoned conduit as a route for hazardous vapors
  10. Leakage
  11. Blocking of emergency access
  12. Other machine, application, or environmental considerations.

These examples of residual hazards can also create conditions that result in fires, explosions, and hazardous material (hazmat) exposures. It has been my experience that decommissioned, out-of-service machines that stay in place also require a comprehensive risk assessment program. All risks associated with these machines must be identified and all measures to mitigate those risks must be implemented so as to reduce those risks to acceptable levels.

This process is, therefore, no different than when the machine was first installed for commissioning and production.

Any questions or challenges with end-of-useful life machines? How do you handle seldom used or mothballed machinery? Leave your advice, questions, or comments with this post online.

- J.B. Titus, certified functional safety expert (CFSE), writes the Control Engineering Machine Safety Blog. Edited by Mark T. Hoske, content manager, Control Engineering, mhoske@cfemedia.com.

ONLINE 

www.controleng.com/blogs has related machine safety posts and other blog topics, including: Does a risk assessment need to be updated for a minor modification to a machine?

Link to the Safety and Security enewsletter at www.controleng.com/enewsletter

ONLINE extra

See related machine safety blog posts below. 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Developing lighting solutions; Designing lighting systems; Integrating fire alarm and HVAC systems
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
Knowing when and how to use parallel generators
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me