Low-voltage switchgear for mission critical environments

Low-voltage switchgear technology designed to extend type 2B arc-resistant ratings with the instrument and breaker secondary door open provides centralized control and protection for low-voltage power distribution equipment.

06/02/2015


Low voltage switchgear technology designed to extend type 2B arc-resistant ratings with the instrument and breaker secondary door open provides centralized control and protection for low-voltage power distribution equipment.Low-voltage switchgear technology designed to extend type 2B arc-resistant ratings with the instrument and breaker secondary door open provides centralized control and protection for low-voltage power distribution equipment. The new switchgear is engineered to improve uptime for data center, oil and gas, mining, utility, and other mission critical industrial applications. The new switchgear design allows access to the control switch and indicator lights located on the breaker secondary doors without opening the main breaker door. Eaton's two-part design allows the circuit breaker door to remain closed while accessing control wire, and retains the C37.20.7 arc-resistant rating during routine maintenance to simplify access to circuit breaker secondary terminals and reduce unplanned downtime. In compliance with NFPA 70E, and as defined by the American National Standards Institute (ANSI) C37.20.7 standard, the arc-resistant low-voltage switchgear carries a hazard risk category of zero for circuit breaker operation with doors closed and latched.

Eaton

www.eaton.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me