Low-voltage switchgear for mission critical environments

Low-voltage switchgear technology designed to extend type 2B arc-resistant ratings with the instrument and breaker secondary door open provides centralized control and protection for low-voltage power distribution equipment.

06/02/2015


Low voltage switchgear technology designed to extend type 2B arc-resistant ratings with the instrument and breaker secondary door open provides centralized control and protection for low-voltage power distribution equipment.Low-voltage switchgear technology designed to extend type 2B arc-resistant ratings with the instrument and breaker secondary door open provides centralized control and protection for low-voltage power distribution equipment. The new switchgear is engineered to improve uptime for data center, oil and gas, mining, utility, and other mission critical industrial applications. The new switchgear design allows access to the control switch and indicator lights located on the breaker secondary doors without opening the main breaker door. Eaton's two-part design allows the circuit breaker door to remain closed while accessing control wire, and retains the C37.20.7 arc-resistant rating during routine maintenance to simplify access to circuit breaker secondary terminals and reduce unplanned downtime. In compliance with NFPA 70E, and as defined by the American National Standards Institute (ANSI) C37.20.7 standard, the arc-resistant low-voltage switchgear carries a hazard risk category of zero for circuit breaker operation with doors closed and latched.

Eaton

www.eaton.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me