Low-voltage direct replacement breaker solutions

Schneider Electric's new low-voltage (LV) direct replacement breaker solutions allow for modernization of existing electrical equipment in any switchgear application.

10/27/2016


Schneider Electric's allows for modernization of existing electrical equipment in any switchgear application. Courtesy: Schneider ElectricSchneider Electric introduced seven new low-voltage (LV) direct replacement breaker solutions for the complete DS circuit breaker product line for SquareD, Cutler-Hammer, and Westinghouse switchgear. The factory-tested and IEEE C37.59-compliant LV solutions include fully loaded direct replacement breakers for all switchgear using the DS/DSII 632 breaker, rated up to 85kA, as well as fused DSL & DSLII breakers rated up to 200 kA/1600 A. The replacement breakers are designed to fit into the existing electrical cubicle, increasing installation efficiency by requiring little to no modification to the switchgear cell and reducing overall downtime. The LV direct replacement circuit breakers provide a flexible solution for customers by enabling them to maintain their familiar DS breaker technology while eliminating the need to pay the premiums associated with purchasing newer models.

Schneider Electric

www.schneider-electric.us



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me