Linear hall-effect magnetic position sensor IC

Honeywell SS39ET series has a low-cost, versatile SOT-23 subminiature surface mount package ideal for compact designs with tight space requirements.

03/13/2012


SS39ET subminiature Linear Hall Effect Sensor ICHoneywell is extending its Linear Hall-effect Sensor Integrated Circuits (IC) product line with the addition of the new SS39ET Series to its SS49E and SS59ET portfolio of low-cost Linear Hall-effect devices.

With the launch of the SS39ET Series, Honeywell’s Linear Hall-effect product family now consists of three package styles with different lead configurations:

  • SS39ET: subminiature SOT-23 surface mount package (tape and reel format)
  • SS49E: leaded flat TO-92 package (bulk packaging, 1000 units per bag), SS49E-T2 (straight leads), and SS49E-T3 (formed leads) on tape in ammopack (fan-fold) format
  • SS59ET: miniature SOT-89B surface-mount package (tape and reel format) 

“With the launch of the new SS39ET Series, customers can choose the package style and size to meet their application needs,” said Josh Edberg, senior global product marketing manager for Honeywell Sensing and Control. “Customers will appreciate the SS39ET Series’ SOT-23 subminiature footprint that takes up less space on the PC board, allowing more design flexibility and cost savings in their application.”
 
The SS39ET Series are designed to monitor magnetic fields from a permanent magnet or an electromagnet. All packages can be supplied on tape for automated, lower-cost assembly. These devices respond to both North and South poles, and can be powered with voltages as low as 2.7 V.
A wide temperature range of -40 C to 100 C [-40 F to 212 F] allows use in many environments, and the thermally balanced, integrated circuit provides stable operation over the full temperature range. Thin film resistors improve accuracy and provide a stable output. The energy-efficient, low current consumption of 6 mA at 5 V dc and the 2.7 V dc to 6.5 V dc supply voltage range allow circuit design flexibility.
 
Potential industrial applications for the SS39ET Series include:

  • Anti-tampering magnetic field sensing in smart remote utility meters
  • Basic current sensing for motor load monitoring, detection
  • Pump control in heavy-duty equipment and household appliances 
  • Simple linear or angular displacement sensing
  • Handlebar/throttle position sensing in e-bikes and scooters 
  • Current sensing in appliances 
  • Speed adjustment trigger in tools and appliances 
  • Magnetic code reading in safes, security, and building access control systems.

Potential medical applications for the SS39ET Series include:

  • Position sensing in infusion pumps

Learn more about Honeywell Sensing and Control 

http://sensing.honeywell.com/

Also see controleng.com/sensors. 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me