Linear drives with manual pitch control

Uhing Model RG linear drives from Amacoil have adjustable pitch, enabling variable speed without changing drive motor speed.

01/11/2013


Uhing Model RG linear drives from Amacoil have adjustable pitch, enabling variable speed without changing drive motor speed. Inset shows pitch control lever. Courtesy: AmacoilAll Uhing Model RG linear drives from Amacoil now feature a manual pitch control which permits a 10:1 adjustment of the linear pitch of the drive unit. Each of seventeen Model RG drive units has a specific maximum linear pitch. This is the linear distance the drive will move on the shaft per one revolution of the shaft. The pitch control lets users turn the pitch down in 0.01 increments across one hundred discrete settings.

In applications where it is desirable or necessary to keep the drive motor running at a constant speed, the adjustable pitch feature enables a variable speed drive system without requiring changes or adjustments to the drive motor speed. If greater linear speed changes are needed than are afforded by the pitch control, then the drive motor speed may be increased or decreased without affecting the linear pitch of the drive. Once the pitch of the drive is set, it will remain the same regardless of the drive motor speed. The pitch will change only if the operator adjusts the pitch control.

In applications where a specific linear pitch range is required, the traverse shaft may be driven via belt and pulley linkage to the main drive shaft. The ratio between the two pulleys establishes the desired linear pitch range. For example if the pulley on the traverse shaft is twice as large as the pulley on the main drive shaft then the drive will move two times its normal pitch per one shaft revolution.

Amacoil Inc.

www.amacoil.com 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me