Lift stage with large aperture offers precise elevation of heavy loads

Aerotech’s AVS1000 series is a high-load lift stage with aperture that offer excellent pitch, yaw characteristics over full travel.

04/22/2011


Aerotech’s AVS1000 series stages offer a solution for applications that require positioning of large or heavy loads over very small incremental movements in elevation above a horizontal plane. The low profile and precise motion capability make these stages ideal for use in semiconductor manufacturing and inspection, automated tool alignment, machine vision inspection systems, laser machining applications, and more.

The AVS1000 series provides precise elevation of a load in a vertical plane using a moving-wedge design. The precision machined wedge block converts horizontal movement from a precision-ground ball screw into vertical elevation of the AVS1000 series tabletop. Excellent pitch and yaw characteristics over the length of travel minimize the impact of angular errors. AVS1000 performance includes exceptional resolution (5 nm) and accuracy (±1 µm), with the ability to apply this performance to large loads up to 135 kg.

Sealed linear motion guide bearings with integral wipers are incorporated to provide excellent payload capability, long life, and smooth, precision motion. Stable and parallel vertical motion with no rocking or horizontal deviation of the platform is assured. Careful design of the wedge angle and bearing system allows the AVS1000 series to achieve submicron resolution and still maintain a compact profile.

The vertical lift approach offers an alternative to traditional Z-plane oriented stages. Not only do the AVS1000 series stages offer a lower profile, but the load can also be conveniently accessed from any side due to the large aperture. And by centering the payload over the bearings, there are no cantilevering effects.

The AVS1000 series includes Aerotech's high performance NEMA 34 frame-size BMS series brushless, slotless servomotor. The slotless motor has zero cogging and therefore is optimized for applications requiring very smooth motion.

Aerotech manufactures a wide range of matching drives and controls to provide a fully integrated and optimized motion solution.

The AVS1000 series specification data is available at the following link.

www.aerotech.com

Aerotech

- Edited by Gust Gianos, Control Engineering, www.controleng.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me