Letters

Better mix: raise high the outdoor air inletEditor's note: "The Right Mix" (Oct. 2001, p. 69) author Gene DeJoannis, P.E., supplies an addendum to his story. In a recent article in CSE, I wrote about the difficulty of insuring good mixing in large factory packaged air-handling units (AHUs), and proposed a compact mixing device to physically "tunnel" cold air into the warm return-air str...

12/01/2001


Better mix: raise high the outdoor air inlet

In a recent article in CSE , I wrote about the difficulty of insuring good mixing in large factory packaged air-handling units (AHUs), and proposed a compact mixing device to physically "tunnel" cold air into the warm return-air stream—the "Injecti-mixer." Although small air handlers permit outdoor air to be connected to the return duct before the AHU—thereby achieving good mixing—I commented that this is not practical for large AHUs because the ducts are so large they do not permit enough room. But there is a way: In cases where the AHU is backed up against an outdoor-air plenum, with the return or exhaust fan suspended in-line in an overhead return duct, the outdoor air plenum can be moved from the floor to ceiling of the mechanical room. This way, the return-air damper is installed in the room side of the outdoor-air plenum and the return duct connected to it. Note that the outdoor- and return-air streams enter nearly opposite each other and both must turn 90° downward and then 90° horizontally to enter the AHU. Although it is risky to predict air-mixing behavior, it seems reasonable that this arrangement will mix air better than traditional practices. Additionally, this reduces the likelihood of pulling in dirt as the inlet is elevated above the outside roof or surface.

GENE DeJOANNIS, P.E., van Zelm Heywood & Shadford

Integrity of fire cabling questioned

Mineral insulated (MI) cable manufacturer, Pyrotenax, has a videotape demonstrating a danger of circuit-integrity cable. When the insulation "ceramifies," it creates a flammable smoke which can spread fire through conduit wired with the U.L. 2126-approved cable. "Circuit Security," (Oct. 2001, p. 55) is silent on this aspect.

HERBERT ARGINTAR, P.E., NSPE

Author Dean Wilson's response: I am not familiar with the video and feel that it would be inappropriate for me to comment on these allegations until I view it myself. With regard to the general topic of smoke migration through conduit: This subject has been discussed in various forums over the years, and I am not aware of any notable fire occurring where propagation of smoke through the conduit played a significant ro le in physical damage or the threat to life.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me