Latest from ASHRAE: Resources for Refrigeration, Commissioning, IAQ, Mold and Load Calculation

05/26/2005


The American Society of Refrigerating, Heating and Air Conditioning Engineers has announced several newly available and planned resources, including:

Design Essentials for Refrigerated Storage Facilities, by Bryan Becker, Ph.D., P.E., professor of mechanical engineering, and Brian Fricke, Ph.D., assistant professor in mechanical engineering, University of Missouri-Kansas City. The book provides guidance on design details such as support structures, doors, docks, underfloor heating, insulation and vapor retarders, as well as facility configuration and layout, refrigeration-system design and facility management.

Guideline 0-2005, The Commissioning Process, a new guideline that can help ensure that the sustainable development principles contained in building rating systems such as the USGBC Leadership in Energy and Environmental Design (LEED) perform as intended. Among other things, it describes how to verify that a facility and its systems meet the owner’s project requirements.

Guideline 10P, Criteria for Achieving Acceptable Indoor Environments, was opened for public comment on May 6 and will remain open until June 20. The proposed guideline calls attention to many interactions that designers might not have previously recognized or understood. It specifies indoor environmental criteria that are acceptable to human occupants and are intended to minimize the potential for adverse health effects.

Minimizing Indoor Mold Through Management of Moisture in Building Systems, is a new position paper that can be downloaded for free via the “position documents” shortcut at ashrae.org . In this new document, ASHRAE takes the position that due to the proliferation of mold in buildings, sound moisture management should take precedence over energy cost savings.

Standard 183P, Methods and Procedures for Performing Peak Heating and Cooling Load Calculations in Buildings Except Low-Rise Residential Buildings, opened for public comment on May 6. Aiming to establish minimum requirements for the methods used to determine peak heating and cooling loads and the input of data into methods, the 183P standard will not dictate a particular method or program. It is intended to establish a minimum level of care that would apply to any method.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me