Jordan & Skala Engineers: PGA Tour Headquarters

Automation, controls; commissioning, retro-commissioning; electrical, power; energy, sustainability; fire, life safety; HVAC, mechanical; lighting; plumbing, piping; and LEED certification

08/09/2018


Engineering firm: Jordan & Skala Engineers

2018 MEP Giants rank: 41

Project: PGA Tour Headquarters

Location: Ponte Vedra Beach, FL, United States

Building type: Office building

Project type: New construction

Engineering services: Automation, controls; commissioning, retro-commissioning; electrical, power; energy, sustainability; fire, life safety; HVAC, mechanical; lighting; plumbing, piping; and LEED certification

Project timeline: September 2018 to November 2020MEP/FP budget:$290,000Commissioning budget:$17,000

Challenges

1. Provide MEP design that can accommodate frequent tenant renovations.

2. Create a desirable atmosphere on the exterior balconies in the hot, humid climate of Florida without using large blade type ceiling fans.

Solutions

1. Designed raised floor system that allows ultimate flexibility on HVAC, electrical,and low-voltage layout with little or no contractor involvement.

2. Designed a way to route building relief air required to maintain proper building pressurization to the balconies,which provides a cooling affect and therefore comfort to occupants gathering on the balcony.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me