IO modules meet safety standards

Siemens has expanded its Simatic ER 200iSP I/O system to meet safety standards IEC 61508 up to SIL 3 or ISO 13849-1 up to PLe e.

09/28/2011


Siemens has expanded its Simatic ET 200iSP I/O system with three new modules to accommodate safety standards IEC 61508 up to SIL 3 or ISO 13849-1 up to PLe e. The modules are suitable for emergency shutdown, boiler protection and fire and gas equipment applications.

The ET 200iSP is a modular I/O system for hazardous areas, including gaseous and dusty atmospheres. Its sensors and actuators are connected directly to a bus system and the I/O system may be mounted in a non-explosion proof cabinet.

The I/O system is FM approved for mounting in Class 1 Div 2 and Class 1 Zone 1 areas connecting directly to devices mounted in Class 1 Div 1 and Class 1 Zone 0 without the need for external safety barriers.

The isolating transformer within the ET 200iSP is a bus isolating transformer, creating a Profibus DP intrinsically safe communications network.

Function modules, including an explosion proof power supply, Profibus DP interface modules, and up to 32 electronics modules in any combination are plugged into terminal modules. The ability to "Hot Swap" the electronic module during operation is a huge customer benefit to avoid costly downtime of stopping the controller. The firmware of the Profibus DP interface module may be upgraded as new firmware is available using a micro memory card (MMC) or over Profibus DP.

Redundancy is available with redundant power supplies and Profibus DP interface modules providing maximum uptime. When used in a redundant configuration, the power supplies are hot swappable and maybe replaced under power even in hazardous locations.

The ET 200iSP is configured and parameterized using Simatic Step 7 or PCS 7 software. Supporting Configuration in Run (CiR) system functions, the ET 200iSP configurations and parameterization may easily be modified during runtime.

Extensive diagnostic information is provided, pinpointing open or closed circuit faults. Fault information is sent to the host system, permitting fast online diagnostics from a central location. Standard diagnostic drivers are available for Siemens Simatic PCS 7 distributed control systems.

Process devices are linked with Highway Addressable Remote Transducer (HART) technology using an analog signal of 4-20 mA. A central station can transparently access HART process devices using a routing function with Profibus DP. As a result, most process instruments, including temperature, fill-level, pressure, and flow rate measuring equipment, may be accessed and configured.

www.siemens.com 

Siemens Industry Inc.

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me