I/O module for RTDs

Opto 22 adds new 1,000 ohm RTD temperature sensing I/O module for its SNAP PAC family.

02/17/2012


Opto 22 has released its new SNAP-AIRTD-1K, a two-channel, isolated analog input module for use with 1,000 ohm platinum RTDs.Opto 22 has released its new SNAP-AIRTD-1K, a two-channel, isolated analog input module for use with 1,000 ohm platinum RTDs (resistance temperature detectors). With the SNAP-AIRTD-1K, Opto 22's line of SNAP I/O modules now includes RTD input modules for use with 10 ohm copper, 100 ohm platinum, and 1,000 ohm platinum probes.

The SNAP-AIRTD-1K module provides two channels of analog temperature input, with a nominal input temperature range of -200 to 850 °C (-328 to 1,562 °F) and an input range of 0-4,000 ohms. The module has an average resolution of 0.042 °C (0.16 ohms). Used primarily with RTD probes to provide temperature inputs, the module can also be used for making high-resolution resistance measurements.

1000 ohm platinum RTD probes are used by engineers and technicians to measure temperatures precisely in industrial furnace and refrigeration applications, HVAC systems, autoclaves, or any application requiring accurate measurement over a wide temperature range. The SNAP-AIRTD-1K module is used in systems based on Opto 22's SNAP PAC (programmable automation controller), and also in SNAP Ethernet I/O systems used for PC-based control applications.

The module is guaranteed for life, is transformer isolated, and like all Opto 22 SNAP I/O modules, is optically isolated from the equipment and devices it connects to, as well as from other modules on a shared I/O rack.

www.opto22.com

Edited by Peter Welander, pwelander@cfemedia.com

Visit the Control Engineering Process Control Channel.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me