International Code Council Takes Action on ASHRAE Proposals

10/25/2006


International building codes may soon incorporate new requirements from ASHRAE standards, thanks to several recent proposals now under consideration.

ASHRAE has made several proposals to the International Code Council (ICC), and after a public review, final hearings for the code change proposals will take place May 21-22, 2007. If the proposals are accepted, they will be included in the 2007 code supplement.

“It is the governmental use of building codes and the conversion of standards into codes that derive the greatest benefit from the ASHRAE standards’ development process,” said Terry Townsend, ASHRAE president, at a meeting with ICC leadership, encouraging adoption of the proposals.

A proposal to include new ventilation rates from ANSI/ASHRAE Standard 62.1-2004, Ventilation for Acceptable Indoor Air Quality , was approved for inclusion in the International Mechanical Code (IMC). The change would lower zone ventilation in many zones, particularly those with high occupant density, and improve overall ventilation results in systems where zones with differing ventilation requirements are served by a common ventilation system.

“For many high-occupant-density zones (like classrooms and places of worship) these new rates reduce outdoor air intake requirements by 50% or more, compared to the IMC,” said Dennis Stanke, chair of the Standard 62.1 committee. “HVAC systems for these buildings can be designed with fewer air-conditioning tons and operated using less energy. Lower intake rates tend to reduce both first cost and operating cost.”

Four proposals written by ASHRAE’s Code Development Committee for ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings , and ANSI/ASHRAE Standard 90.2-2004, Energy-Efficient Design of Low-Rise Residential Buildings , were approved for inclusion in the International Energy Conservation Code.

• EC39: Lowers the solar heat gain coefficient requirements in residential buildings in Climate Zones 1 and 2 to 0.37 from 0.40. This requirement is consistent with Standard 90.2-2004.

• EC84: Adds a U-factor table to the code and add definitions for C-Factors, and F-Factors.

• EC98: Adds a requirement for hot-gas-bypass to the code.

• EC125: Revises exterior lighting control requirements.

Also related to its energy standard, ASHRAE plans to submit a public comment on a proposal to provide R-Value, U-Factor requirements and removal of the Standard 90.1 envelope section as a compliance method. ASHRAE opposes approval of proposal EC82 because it removes a partial reference to Standard 90.1.

Also approved was a proposal to make the IMC more consistent with ANSI/ASHRAE Standard 34-2004, Designation and Safety Classification of Refrigerants . The change would add new refrigerants for which the standard has given a designation and safety classification. The addition will facilitate use of these refrigerants.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me