Integrating safety in automation requires specialized knowledge

In a typical automation project, maximum efficiency is key. However, undertaking a safety automation project presents additional challenges. First, legal requirements must be met. Second, care must be taken to ensure and validate that the application is truly safe. For example, is safety ensured if the equipment is misused or fails? Are you ready? Do you need a risk assessment?

08/11/2010


In a typical automation project, maximum efficiency is key. However, undertaking a safety automation project presents additional challenges. First, legal requirements must be met. Second, care must be taken to ensure and validate that the application is truly safe. For example, is safety ensured if the equipment is misused or fails?

‘Muting’ a light curtain is accomplished with additional sensors. When the sensors detect a pallet, the safety light curtain is muted. This configuration is done with a safety PLC; a safe and pre-certified muting function block ensures safe suspension of the light curtain (Source: Sick).Many people—including health and safety engineers, consultants, and safety equipment suppliers—are involved in performing a risk assessment and creating a safety plan. Fewer have a role in determining, commissioning, and implementing safety technology. In fact, often it is up to the integrator alone.

During typical automation projects, PLC programmers must adapt the system to the real-world environment and makes changes “on the fly” to get the project up and running. They often use “OR” function blocks (parallel contacts in ladder logic) and active low sensors. Both are highly critical when doing safety programming.

Consider, for example, a safety application where material has to get out of a machine, but neither a person nor any material is allowed in. This arrangement can be accomplished by “muting” a light curtain using additional sensors. Muting refers to an automatic, temporary suspension of the safety device. When the sensors detect a pallet, the safety light curtain is muted.

This configuration can be done with a safety PLC. A safe and pre-certified muting function block ensures safe suspension of the light curtain (see the diagram). Assume that the muting sensor is a reflector switch where the output is “HIGH” when it sees a reflector and “LOW” when an object is in the light path. The muting function block needs to be “HIGH” on the sensor input to mute the light curtain.

An inexperienced integrator might see no problem with this situation, saying, “Let’s negate the signal by using a ‘NOT’ function block.” Although such a solution works well and appears safe, what happens if the common power supply for the two sensors breaks down? Both sensors will switch off and it will appear to the safety PLC that they both see the object. As a result, the light curtain will be suspended.

An unsafe situation can occur easily by adapting a safe concept (function block) to a real-world scenario. An integrator needs to know his/her determination methods will influence the application. In this case, use of active “HIGH” sensors in combination with additional control signals or time monitoring functions would be required.

Integrating safety technology in a practical way requires extensive knowledge, application expertise, and many years of experience. Just as you would carefully select a qualified integrator for an automation project, make sure to do the same for the safety portion of the project by keeping them separate. This approach will ensure that safety is left to the experts. Experienced safety integrators will reduce the likelihood of safety risks during all phases of a project. Making use of simple and easy-to- use tools for design, simulation, and test also will help validate the safety functions throughout the life cycle of a machine or project.

- Juergen Bukowski is safety program manager, Sick Inc., Minneapolis, MN. Edited by Jeanine Katzel, consulting editor, Control Engineering, www.controleng.com

www.sickusa.com

Also see the Control Engineering:

Machine Safety blog

Machine Control Channel

System Integration Channel



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me