Integrated motion servo drive with EtherNet/IP connectivity

Kinetix 5500 servo drive by Rockwell Automation joins the Kinetix 350 and Kinetix 6500 drives to provide users with more options to match motion control needs.

12/13/2012


The Kinetix 5500 servo drive by Rockwell Automation joins the Kinetix 350 and Kinetix 6500 drives to provide users with more options to match motion control needs. Courtesy: Rockwell AutomationRockwell Automation's Allen-Bradley Kinetix 5500 servo drive, Kinetix VP low-inertia (VPL) servo motor, and single-cable technology as an integrated motion solution on EtherNet/IP that is more compact, easier to use and simplifies system wiring.

The Kinetix 5500 servo drive joins the Kinetix 350 and Kinetix 6500 drives to provide users with more options to match motion control needs. Integrated motion control on EtherNet/IP eliminates the need for a dedicated motion network, reducing cabling by up to 60% and removing the need to create gateways to get information to or from secluded networks. Additionally, the Kinetix VPL motors new winding technology and DSL encoder, connected with the smart-cable technology, allows power transmission and feedback communication to and from the Kinetix 5500 drive to take place on one cable. This further simplifies application design and limits points-of-failure for improved reliability and uncomplicated maintenance.

The Kinetix 5500 and Kinetix VP drive-motor system does not require discrete power rail or additional accessories, so machines can be scaled up as needed. Optimally matched motor and drive ratings uses half the energy of comparable solutions, while still providing 125 μsec loop closure for maximum performance.

The Kinetix 5500 drive uses an external common ac/dc bus connection system. It reduces hardware requirements and allows for seamless scalability, using a single platform for either single-axis or multiaxis systems. The Kinetix 5500 drive also has the ability to control both servo and induction motors, provide best–in-class power density that reduces the size of the drive and cabinet space required by up to 50%, and simplify machine maintenance by minimizing the need to fuse or use contactors.

Rockwell Automation

www.rockwellautomation.com 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me