Integrated kitchen ventilation system

Greenheck’s Vari-Flow integrated kitchen ventilation systems reduce energy costs by modulating exhaust and supply airflows to match cooking operation demands and have temperature sensors that are exposed to quick changes in cooking activity.

07/31/2013


Greenheck’s Vari-Flow integrated kitchen ventilation systems reduce energy costs by modulating exhaust and supply airflows to match cooking operation demands and have temperature sensors that are exposed to quick changes in cooking activity. Courtesy: GrGreenheck’s Vari-Flow integrated kitchen ventilation systems allow food service managers and building owners to reduce energy costs by more precisely modulating exhaust and supply airflows to match cooking operation demands. Temperature sensors located in the hoods’ capture area are directly exposed to quick changes in cooking activity that result in a five times faster response to cooking load changes. This feature, coupled with fan-speed turndown of 50% and high-efficiency Vari-Green motors, offers total energy savings in terms of electrical, heating, and cooling costs. Greenheck’s Vari-Flow kitchen ventilation system can be controlled with a keypad or the touchscreen control that features independent light and fan control, programmable fan scheduling, VFD and help diagnostics to monitor energy usage, and live/historical energy monitoring and trending. The Vari-Flow system is compatible with BACnet MSTP/IP, LON, and ModBus to easily integrate the system into a wide range of building management systems. 

Greenheck 

www.greenheck.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me