Integrated design solutions to improve energy efficiency

To resolve the issue of improving efficiency while making projects more cost-effective, disciplines must work together toward integrated design solutions.

01/25/2017


Modular bathroom design for a luxury hotel. Courtesy: Rafael LopezToday's technologies allow architects and owners to dream big and design and construct more sophisticated facilities that provide unique and interesting experiences for the user. Architects are now collaborating more with their consultants and with contractors early in the design phase, and owners are providing big rooms for the entire team to meet and collaborate daily, face to face.

At the same time, increasing project complexity is requiring specialized expertise for design and construction. As a result, engineers have become experts in the various market sectors they service. However, this can create silos of knowledge that leave gaps in the project team's ability to deliver energy-efficient and sustainable buildings. To resolve this issue of improving efficiency while making projects more cost-effective, disciplines must work together toward integrated design solutions.

Here are some opportunities to consider:

Radiant floor slabs and cross-linked polyethylene (PEX) tubing can provide the majority of heating and/or cooling for the occupied spaces, provided the tubing is coordinated with the stressed tendons within the floor slab. Courtesy: GlumacPrefabrication. Glumac is designing skid systems for major mechanical and electrical systems and entire rooms. These skids are designed with full mechanical, engineering, and plumbing (MEP) systems and allow for continuous comprehensive commissioning.

Radiant floor slabs. Most commercial construction projects include concrete floors. In this type of environment, radiant floor slabs and cross-linked polyethylene (PEX) tubing can provide the majority of heating and/or cooling for the occupied spaces, provided the tubing is coordinated with the stressed tendons within the floor slab.

Radiant ceiling panels in open office environment. Courtesy: Ryan GobutyRadiant ceiling panels. Cooling is typically provided from active or passive overhead chilled beams. Installing the PEX tubing within the structural slab above provides an economical and aesthetically pleasing means of routing the chilled-water supply and return piping. Similarly, the tubing must be coordinated with the stressed tendons.

Thermal mass. Buildings with concrete floors and roofs provide an opportunity to flush the building during cool periods with no mechanical cooling. This enables the facility engineer to modulate the HVAC system within the building and take advantage of the thermal lag during occupied hours.

Auger piles. This is a common method for providing structural footings for buildings. Once the hole is drilled, a rebar cage is dropped into the hole, which is then filled with concrete. PEX tubing can be connected to the rebar cages to form a geothermal pile, allowing heat to be absorbed or rejected into the ground.

Rooftop photovoltaic array. Courtesy: GlumacPhotovoltaic (PV) canopies. Building-integrated photovoltaic (BIPV) panels can be connected to the fa├žade to provide shading and/or equipment screening while generating electricity. Current PV technologies, such as glazing and roofing systems with integrated PV collectors, are other possibilities for generating electricity without having an impact on the structure's architectural aesthetics.

Integrated controls. Historically, each of the low-voltage trades have worked separately and independently-including lighting, fire alarm, security, audio/visual, and building-system management. Now with fiber optics and wireless devices, these systems are being integrated to reduce costs, improve flexibility, and enable facilities engineers to quickly and easily modify setpoints and schedules. This enhances energy efficiency and tenant comfort.

Thermal chilled-water storage. Many modern high-rise towers include a multilevel, belowgrade parking structure. Based on the requirement for a fire-water storage tank on the lowest level, there is often an opportunity to increase the size of the tank and provide a thermal separation by adding a chilled-water thermal vault. The size of the water vault must be coordinated with the structural mat foundation to assure proper sizing and location.

Motorized shading in open office environment. Courtesy: Rafael LopezMotorized shading. New technologies associated with motorized blinds and photo sensors enable multiple energy-saving and comfort opportunities. The programming allows the facilities engineer to close blinds during unoccupied hours to help reduce the cooling load and enhance energy efficiency. The automation function creates a comfortable space for occupants that is filled with natural light and minimizes glare.

As more architects and engineers in multiple disciplines begin working together collaboratively, integrated design solutions become more common and effective. Integrated design solutions need to be promoted to save owners money and provide better and more sustainable projects. 


-Streven Straus is the president of Glumac, a CFE Media content partner. This article originally appeared on www.glumac.com.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me