Integrated controllers for HVAC applications

The SmartME Zone Controller, the AdvancedHVAC Input/Output Controller, and the EB-50GU-A Central Controller by Mitsubishi Electric Heating and Cooling combine to support enhanced functions.

07/29/2013


Mitsubishi Electric Cooling & Heating Division’s integrated controls solution for commercial HVAC applications uses three advanced controllers: the SmartME Zone Controller, the AdvancedHVAC Input/Output Controller, and the EB-50GU-A Central Controller. They work together as a comprehensive system to support enhanced functions. The SmartME Zone Controller can control up to 16 indoor units in a single zone. The controller features an intuitive, backlit touchscreen interface with dual setpoint functionality and LED color status indicator. The AdvancedHVAC Controller features customizable applications for integrating CITY MULTI indoor units with third-party equipment such as auxiliary heat, fans, pumps, air handling units (AHUs), energy recovery ventilation (ERV) systems, humidifiers, and economizers. The EB-50GU-A Central Controller uses Web-based centralized control of up to 50 indoor units individually in a group or batch operation. The controller offers new features such as expanded monitoring, control, and trending abilities. The EB-50GU-A supports the humidity, occupancy, and brightness sensors on the SmartME Remote Controller. 

Mitsubishi Electric Heating & Cooling 

www.mehvac.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me