Integrated automation solution added to Chinese manufacturing facility

On-schedule factory acceptance of complete automation solution marks important milestone for Zhuhai plant that is cornerstone of Lubrizol 10-year investment plan.

09/27/2013


On-schedule factory acceptance of complete automation solution marks important milestone for Zhuhai plant that is cornerstone of Lubrizol 10-year investment plan. Courtesy: Emerson Process ManagementEmerson Process Management and The Lubrizol Corporation have completed on-schedule, on-budget factory acceptance of Emerson’s integrated automation solution for Lubrizol’s greenfield additives manufacturing facility in Zhuhai, China. Emerson is the Main Automation Contractor for the plant, which will offer select additive component manufacturing as well as additive package blending.

The Zhuhai plant is the cornerstone of Lubrizol’s 10-year investment plan to upgrade operations and increase global capacity in additives. Lubrizol will phase in select capacity additions at the facility to meet market demand.  

At Zhuhai, Emerson’s Main Automation Contractor role includes collaborating with the Lubrizol team to engineer, project-manage, install and commission a complete automation solution for the new additives plant. The Emerson solution is based on a front-end engineering and design (FEED) study done previously at Lubrizol’s facility in Deer Park, Texas.

Emerson’s DeltaV system will manage more than 2900 inputs and outputs, including Rosemount measurement and analytical instruments, Micro Motion Coriolis meters, Fisher control valves and regulators, and on-off valves with FieldQ actuators – a total of almost 1900 Emerson measurement and control devices.  

The system and devices are digitally integrated using IEC 62591 (WirelessHART), Foundation fieldbus, and Profibus communications. Emerson’s DeltaV Electronic Marshalling with CHARMs technology helps simplify engineering and installation by eliminating many of the wires and connections required by traditional marshalling.

Emerson Process Management

www.emersonprocess.com 

- Edited by CFE Media. See more Control Engineering diagnostics and asset management stories.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me