Industrial grade flush touch screen panel PC

To give users increased flexibility when selecting an industrial grade Panel PC, Nexcom has added two Intel Atom D525 CPU based platform.

07/26/2011


15-in Intel Atom D525 CPU based platform. Courtesy: NexcomNexcom added two 15-in Intel Atom D525 CPU based platforms which support resolutions by up to 1024x768 to their line of available products. APPC 1520T/1521T hosts a range of power inputs and an abundance of useful I/O interface features.

The Intel Atom D525 processor features, low power consumption and a small package size. By incorporating the Intel Atom D525 processor and DDR3 memory, the fanless panel PC, APPC 1520T Series, has reportedly doubled the computing power of similar N270 CPU based products. With multiple power inputs, from 12 V to 30 V, APPC 1520T Series is a good solution for telecoms, factory and machine applications.

The all-in-one compact APPC 1520T Series hosts a variety of I/O interfaces which offers a number of connecting capabilities for controlling subsystems and automation hardware, such as devices within warehouse, logistics and access control. In addition, the back cover can be easily removed to access the additional 2.5-in HDD and two mini-PCIe installation for wireless application.

The front IP65 compliant panel provides protection from water and moisture damage which allows users to clean the surface directly using high-pressure water jets. This feature makes the APPC 1520T series suitable for applications where stringent hygiene levels are important, such as within the food and beverages industry. Nexcom's APPC 1520T Series has a special HDD damper which protects the device from shock and vibration.

Two variants are available, APPC 1520T is the standard platform, whilst APPC 1521T has two RS-232/422/485 COM ports with isolation to address industrial applications plus two additional RS-323 COM ports. In addition, one GPIO port for 4 input/output is available for digital control. There is also an optional CAN bus interface to communicate with CAN bus devices.

www.nexcom.com

Nexcom

See more industrial HMI and operator interface developments at

http://www.controleng.com/new-products/hmis-and-operator-interfaces.html



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me