Industrial fan

The Powerfoil X2.0 industrial fan is from Big Ass Fans.

06/21/2012


The Powerfoil X2.0 industrial fan by Big Ass Fans. Courtesy: Big Ass FansThe Powerfoil X2.0 industrial fan introduces an airfoil system—a system that combines patented airfoils and winglets with patent-pending AirFence technology to increase overall coverage by 28%. The winglet improves airfoil effectiveness by eliminating efficiency-robbing turbulence at the tip, while the AirFence captures air that would otherwise slip off the end of the airfoil. Certain features of the original Powerfoil X remain, including the time-tested Nitroseal Drive gearbox for durability and protection. This gearbox features <11 arc minutes backlash HeliCamber gear technology, SKF tapered roller bearings, a 2.5-in. hollow output shaft, Simrit double-lipped output seals, and lifetime synthetic oil. It is available in sizes of 8 to 24 ft.

Big Ass Fans

www.bigassfans.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me