Indiana school to drill geothermal wells on campus

Ball State University is in the process of drilling wells to create geothermal energy on their campus.

07/31/2009


Ball State University (BSU), located in Muncie, Ind. has figured out a way to partially power their 660-acre campus with renewable energy: drill 400-ft deep geothermal wells through athletic fields, parking lots, and lawns.

In an article in the Christian Science Monitor by Mark Clayton, BSU Director of Engineering Jim Lowe said that the school is committed to energy conservation, and that the wells were the best way to supply efficient heating and cooling to approximately 50 buildings. BSU expects nearly 4,000 wells to be dug, though each will be covered up when the Earth smoothes them over.
Each well will be five inches in diameter and 400 ft deep, and equipped with two loops of polyethylene piping-one for cold water, one for warm. When it's winter, the cold water will flow to the fields and down the wells to absorb heat from the surrounding earth, which stays around 55 degrees F year-round. Water warmed by the wells will flow back to a heat exchanger that collects and concentrates the warmth to heat buildings. To cool those same buildings in summer, the process reverses: Water warmed by the heat exchanger is cycled into the wells, where it is cooled by the surrounding earth.
Lowe expects BSU to save an estimated $2 million/year in fuel costs while halving the campus's yearly carbon dioxide emissions - an 85,000-ton cut.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me