In the Blogs at csemag.com

David Sellers, who blogs “A Field Guide For Engineers” posted the first part of a discussion on damper tests at the end of May, and has already posted Part 7B. “I recently had a chance to test the flow vs. damper blade position characteristics for the AHU1 economizer dampers at the Pacific Energy Center (PEC),” Sellers said.

07/01/2007


David Sellers, who blogs “A Field Guide For Engineers” posted the first part of a discussion on damper tests at the end of May, and has already posted Part 7B. “I recently had a chance to test the flow vs. damper blade position characteristics for the AHU1 economizer dampers at the Pacific Energy Center (PEC),” Sellers said. “We discovered a few interesting things, including that theory didn't match reality, at least for our test.”

In Part 2, he looked at the scoping process that led his researchers to develop the test, and he said that readers may find these techniques useful in their own projects. Part 3 looked at techniques that allowed the researchers to assess the performance of the economizer dampers in an air-handling unit. In the post, he discussed why low damper velocities and non-linear damper performance might be cause for concern with respect to economizer damper performance. In Part 4, the researchers said that economizer damper velocity affects the ability of outdoor air and return airstreams associated with an economizer process to mix. Higher velocities translate to more momentum, allowing one airstream to penetrate the other and promote mixing.

Part 5 launched into the testing background, and Part 6 introduced the notion that minimum outdoor air requirement for the facility fell into three components: air required for ventilation purposes, air required to make up for the kitchen hood exhaust, and air required to ensure positive pressurization in the entry lobby. Finally, Parts 7A and 7B describe the test results.



Forum

Educational Opportunities

The webcast, “Power Quality: Understanding Harmonics” hosted by Plant Engineering magazine is available in the webcast archives at

The Construction Specifications Institute and BuildingGreen, Inc., have agreed to work together on the implementation of GreenFormat™, an online reference source of green building product and manufacturers, at



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me