Important updates to water efficiency standards for plumbing fixtures

In an effort to promote conservation of water in residences and businesses, the U.S. Environmental Protection Agency (EPA) created the WaterSense Program in 2006.

04/28/2016


In an effort to promote conservation of water in residences and businesses, the U.S. Environmental Protection Agency (EPA) created the WaterSense Program in 2006. Courtesy: RTM EngineringIn an effort to promote conservation of water in residences and businesses, the U.S. Environmental Protection Agency (EPA) created the WaterSense Program in 2006. This national program certifies fixtures for indoor and outdoor use that consume significantly less water than the federal minimum.

Although the program is voluntary on the federal level, nine states have implemented stricter water efficiency standards for plumbing fixtures, and others are sure to follow. For example, the Illinois Administrative Code was amended in late 2014 to include a requirement that stipulates new and replacement plumbing fixtures need to bear the WaterSense label. The amendment has not been adopted into the state's plumbing code yet—it is expected to be included in the next revision—but many local municipalities already have begun enforcing the water conservation method.

As more projects will call for WaterSense-labeled fixtures, the EPA recently released a final specification for the flushometer-valve toilet that meets the 1.28-gal/flush (gpf) requirement. A flushometer-valve toilet consists of two main components—the toilet bowl and the flushometer valve—and typically are found in commercial, industrial, and institutional facilities.

Flushometer-valve toilets with the WaterSense label provide 20% savings over the federal standard of 1.6 gpf, promoting water conservation that leads to lower water and wastewater bills. According to WaterSense, a 10-story office building with 1,000 occupants could save nearly 1.2 million gal of water and nearly $10,000/year by replacing inefficient flushometer-valve toilets with WaterSense-labeled models. To safeguard against plumbing systems functioning ineffectively, WaterSense also has included a minimum flush volume of 1.0 gpf.

To discuss how water-efficient standards could affect your project and how to realize significant water savings through smart plumbing design, contact an expert at RTM.


This article originally appeared on RTM EngineeringRTM Engineering is a CFE Media content partner.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me