Hydronic boiler

Multifuel condensing hydronic boiler is capable of being fired with natural gas, propane, or #2 fuel oil at facilities requiring backup fuel and is available in 3 to10 million Btu/h capacities.

02/05/2016


Multifuel condensing hydronic boiler is capable of being fired with natural gas, propane, or #2 fuel oil at facilities requiring backup fuel and is available in 3 to10 million Btu/h capacities. Courtesy: AercoAERCO's Multi-Fuel Condensing (MFC) hydronic boiler is capable of being fired with natural gas, propane, or #2 fuel oil at facilities requiring backup fuel. Six MFC models are available in 3 to10 million Btu/h capacities. The boilers have a 5:1 turndown ratio when firing on natural gas or propane. A heat exchanger built with a combination of carbon steel and 316Ti stainless steel offers corrosion resistance against acidic flue gas condensation. The maximum working temperature of 240˚F allows it to meet the requirements of high-temperature applications. The MFC is designed for condensing applications in closed-loop hydronic systems such as in health care buildings, military bases, emergency shelters, and industrial operations.

AERCO

www.aerco.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me