HVAC for Data Centers

When developing data center energy-use estimations, engineers must account for all sources of energy use in the facility.

07/13/2016


When developing data center energy-use estimations, engineers must account for all sources of energy use in the facility. Most energy consumption is obvious: computers, cooling plant and related equipment, lighting, and other miscellaneous electrical loads. Designing efficient and effective data centers is a top priority for consulting engineers. Cooling is a large portion of data center energy use, second only to the IT load. Although there are several options to help maximize HVAC efficiency and minimize energy consumption, data centers come in many shapes, sizes, and configurations. By developing a deep understanding of their client's data center HVAC requirements, consulting engineers can help maintain the necessary availability level of mission critical applications while reducing energy consumption.

The focus of this webcast is to present high level topics on data center energy use and efficiency. Items related to developing highly efficient cooling strategies based on data center type and location, to calculating inefficiencies in electrical systems and the resulting impact on the cooling system energy use will be explored. The topics are essential for any mechanical engineer designing data center cooling systems and providing energy analysis.

Learning objectives:

  • The audience will learn about codes and guidelines, such as ASHRAE 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings, and U.S. Green Building Council LEED v4
  • Attendees will learn the relationships between HVAC efficiency and power usage effectiveness (PUE)
  • Viewers will understand the advantages and drawbacks of using an elevated IT equipment inlet temperature
  • Viewers will learn how running IT equipment at partial load affects data center energy efficiency.

Speakers:

Bill Kosik, PE, CEM, BEMP, LEED AP BD+C, HP Enterprise Business, Technology Services, Chicago

Tom R. Squillo, PE, LEED AP, Environmental Systems Design Inc., Chicago

Moderator: Jack Smith, Consulting-Specifying Engineer, Pure Power, and CFE Media, LLC



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me