How does your hospital stack up: Report examines electricity, fossil fuel, water/sewer, carbon footprint

The Grumman/Butkus Associates 2015 Hospital Benchmarking Survey has been released. Hospitals’ energy costs per square foot have fluctuated greatly since 1999. Energy use intensity (Btu/sq ft/year) fell in 2014 after a fairly sharp rise in 2013, probably due to a somewhat milder winter in 2013-14 versus 2012-13.

03/11/2016


Hospitals’ energy costs per square foot (red boxes) have fluctuated greatly since 1999. Energy use intensity (Btu/sf/year) fell in 2014 after a fairly sharp rise in 2013, probably due to a somewhat milder winter in 2013-14 vs. 2012-13. Courtesy: Grumman/B

Grumman/Butkus Associates has released the results of its 2015 Hospital Energy and Water Benchmarking Survey, focusing on healthcare facilities' resource usage trends and costs for calendar year 2014.

Since the survey was initiated 20 years ago, hospitals' overall fossil fuel use has trended downward, but electricity use isn't declining much. The average combined Btu/sq ft for facilities in the survey (electricity plus gas/steam) was 232,981 in CY2014, compared with 248,456 in the 2014 survey (CY2013). (Harsher winter temperatures in 2012-13 compared with 2013-14 likely had something to do with the usage decline.)

Square-foot prices for gas/steam were up year-to-year ($1.01 in 2013, vs. $1.16 in 2013), but square-foot prices for electricity fell ($2.26 in 2013 versus $2.12 in 2014). The overall result of these usage and pricing patterns was that hospitals' total sq ft costs for energy (gas/steam plus electric) hardly changed: $3.29 in CY2014, versus $3.27 in CY2013.

Carbon footprint results have stayed fairly steady over time, at about 60 pounds of CO2 equivalent per sq ft/year, but have been slowly trending downward since 2010.

Reporting facilities displayed a broad range of usage patterns. For instance, some participants are using more than 200,000 Btu/sq ft in fossil fuel annually, compared with a general mid range of facilities (about 150,000 Btu/sq ft/year) and those that used least (100,000 Btu/sq ft/year). Similarly, a few hospitals consume more than 40 kWh/sq ft/year in electricity, compared with a mid-range of about 25 kWh/sq ft/year. A few squeaked by with less than 20 kWh/sq ft.

"Hospitals are investing in efficiency measures and making progress, but have much further to go," said G/BA Chairman Daniel L. Doyle. "Some of the low-hanging fruit is gone, but there are still many cost-effective opportunities remaining for reducing energy usage and costs."

Hospital water use is also gradually declining, currently averaging about 49 gallons per square foot per year (compared with nearly 70 gallons/sq ft/year a decade ago). Costs per gallon are rising, however, now averaging $0.38/sq ft. As recently as 2007, hospitals were paying just $0.27/sq ft. "The downward usage trend reflects a movement to eliminate city-water-cooled equipment, as well as the increased use of low-flow and occupancy-based plumbing fixtures," said Doyle. "Water usage is an emerging issue. There is still much room for improvement."

The G/BA survey has provided a free annual benchmarking resource since its initial release in 1995. Hospitals are invited to participate without charge by submitting responses to a short list of questions. Information for this edition was provided by 117 hospitals located in Illinois (56), Wisconsin (33), Michigan (5), Indiana (5), and seven other states.

Full results and analysis, as well as information about participating in the 2015 survey, are available on the firm's website



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me