HOK/Vanderweil wins Next Generation Design Competition

A team of engineers from HOK and Vanderweil won the award from Metropolis magazine for their proposal in retrofitting a 1960s building using new energy.

06/06/2011


A team of architects and engineers from HOK and Vanderweil Engineers won Metropolis Magazine’s Next Generation Design Competition. Their proposal, titled “Process Zero: Retrofit Resolution” was designed to retrofit a Los Angeles federal building owned by the General Services Administration (GSA) designed in the 1960’s using new energy solutions.

The Washington, D.C.-based team’s proposal demonstrated how the building used in their proposal could yield an 84% reduction in overall energy demand through energy conservation and renewal. On-site energy generation—used via a modular system of algae tubes designed to absorb the sun’s radiation for energy production on the building’s façade—would supply the remaining 16%. The proposal also includes a 25,000-square-foot microalgae bioreactor system able to generate 9% of the building’s power supply once the retrofit is complete.”

Some of the highlights in the proposal include:

  • Radiant floor heating
  • Geothermal cooling
  • Rainwater harvesting
  • Energy recovery mechanical ventilation
  • Phase-changing insulation material in ceilings to help extend natural ventilation periods
  • Daylight controls to reduce artificial lighting energy consumption by 75%.

These new energy proposals and concepts were what won over the Next Generation jury, giving the 15-person Washington, D.C., team the top prize.

Metropolis magazine featured the winning proposal in the May 2011 issue.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me