High voltage instrument for semiconductors

Keithley Instruments' Model 2657A High Power System Sourcemeter is designed to source up to five times as much power to a device under test as the nearest competitive system, at significantly lower cost, the company said.

04/05/2012


Keithley Instruments' Model 2657A High Power System Sourcemeter is designed to broaden the range of power semiconductor devices and materials. Courtesy: KeithleyKeithley Instruments, Inc. introduce their Model 2657A High Power System SourceMeter instrument. The Model 2657A adds high voltage to the company’s Series 2600A System SourceMeter family of precision source measurement units. Together, these instruments allow an even broader range of power semiconductor devices and materials. A built-in 3,000 V, 180 W source allows the Model 2657A to source up to five times as much power to a device under test as the nearest competitive system, at significantly lower cost. The precision, high speed 6-1/2-digit measurement engine built into the Model 2657A enables 1fA (femtoamp) current measurement resolution to support the low-leakage requirements of next-generation power semiconductor devices.

The Model 2657A is optimized for high voltage applications such as testing power semiconductor devices, including diodes, FETs, and IGBTs, as well as characterizing newer materials such as gallium nitride (GaN), silicon carbide (SiC), and other compound semiconductor materials and devices. It is also useful for characterizing high speed transients and performing breakdown and leakage tests on a variety of electronic devices at up to 3,000V.

The Model 2657A also offers a flexible, four-quadrant voltage and current source/load coupled with precision voltage and current meters. It combines the functionality of multiple instruments in a single full-rack enclosure: semiconductor characterization instrument, precision power supply, true current source, 6-1/2-digit DMM, arbitrary waveform generator, voltage or current pulse generator, electronic load, and trigger controller, and is fully expandable into a multi-channel, tightly synchronized system via Keithley’s TSP-Link technology. The Model 2657A can source or sink up to 180W of DC power (±3,000V@20mA, ±1500V@120mA). The Model 2657A also offers 1fA resolution, allowing it to make fast, accurate sub-picoamp measurements even when sourcing up to 3000V.

Keithley Instruments, Inc.

www.keithley.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me