High standards for labs, research buildings: Electrical, power systems

Laboratory and research facilities are high-performance buildings, often with complex systems and exacting standards for engineers to meet. Electrical and power demands are unique, and must be carefully designed.

05/23/2014


Bryan Laginess, PE, LEED AP, Senior associate, Peter Basso Associates, Troy, Mich. Jeremy Lebowitz, PE, Vertical market leader, Rolf Jensen & Associates Inc., Framingham, Mass.Brian Rener, PE, LEED AP, Associate, SmithGroupJJR, ChicagoJoshua Yacknowitz, PE, LEED AP, Associate principal, Arup, New York City

  • Bryan Laginess, PE, LEED AP, Senior associate, Peter Basso Associates, Troy, Mich.
  • Jeremy Lebowitz, PE, Vertical market leader, Rolf Jensen & Associates Inc., Framingham, Mass.
  • Brian Rener, PE, LEED AP, Associate, SmithGroupJJR, Chicago
  • Joshua Yacknowitz, PE, LEED AP, Associate principal, Arup, New York City

Engineers at RJA Group are working on the Novartis Institutes for BioMedical Research in Cambridge, Mass. Situated near the Massachusetts Institute of Technology, the project includes two buildings with 550,000 sq ft of laboratory and office space. Courtesy: Rolf Jensen & AssociatesCSE: Describe some recent electrical/power system challenges you encountered when designing a new building or working in an existing building.

Rener: Certain research equipment may require either nontypical voltages such as 400 V or may require special electromagnetic interference (EMI) considerations. This may require the room to be built with shielding in the walls, or special lighting to reduce interference. In addition, we often get requests for “isolated grounding” from researchers, and this requires a careful discussion of what “isolated” means, as all grounding systems must be bonded together at some point.

CSE: How do you balance the need for reliable power with the desire for efficiency and sustainability?

Rener: There has been a greater push for efficient and suitable backup power systems, particularly with UPS and rotary systems. We are seeing efficiencies upwards of 98% to 99% in certain UPS types. The increased use of rotary systems is following the green trend to reduce or eliminate batteries due to their short life span, disposal concerns, and embodied carbon footprint.

CSE: What low- and medium-voltage power challenges have you overcome? 

Rener: In some research facilities using high-performance computing, we are seeing increasing use of 400 V systems. This is great from an energy perspective, but provides some safety challenges to local users and maintenance staff relative to arc flash. Medium-voltage systems also require additional working space by code and for operations of certain types of gear. Space planning with the architect for medium-voltage gear in electrical rooms is critical.

CSE: Describe a recent laboratory/research facility project in which you specified standby or emergency power. What challenges did you face, and how did you overcome them?

Rener: There was a project whereby the standby power systems used both generators and rotary UPSs. There was a concern about coordinating the ramp-up time of the generator and the window of the rotary spin down. This required very careful requirements to be put in the specifications to ensure compatibility between the generator and the rotary UPS manufacturers. In addition, it is important to clearly delineate emergency from standby or optional loads as they have drastically different code requirements.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me