High-performance medical and educational building design: HVAC

The design of high-performance medical and educational projects are challenging and need to meet specific standards, codes, and trends. There can be unique HVAC system requirements for high-performance buildings.

06/30/2016


Joseph A. D’Alù, PE, LEED AP, CEM, Division Manager, RMF Engineering,Charlottesville, Va. Courtesy: RMF EngineeringTG Davallou, LEED AP, Partner, Alfa Tech Consulting Engineers, San Francisco. Courtesy: Alfa Tech Consulting EngineersSean Donohue, PE, LEED AP, Director, Colorado Springs, Jensen Hughes, Colorado Springs, Colo. Courtesy: Jensen HughesAnthony B. Preteroti, Associate Vice President, CannonDesign, Grand Island, N.Y. Courtesy: CannonDesignTeresa Rainey, PE, LEED Fellow, Director of High-Performance Design, EYP Architecture & Engineering, Washington, D.C. Courtesy: EYP Architecture & Engineering

Respondents

Joseph A. D'Alù, PE, LEED AP, CEM, Division Manager, RMF Engineering, Charlottesville, Va.

TG Davallou, LEED AP, Partner, Alfa Tech Consulting Engineers, San Francisco

Sean Donohue, PE, LEED AP, Director, Colorado Springs, Jensen Hughes, Colorado Springs, Colo.

Anthony B. Preteroti, Associate Vice President, CannonDesign, Grand Island, N.Y.

Teresa Rainey, PE, LEED Fellow, Director of High-Performance Design, EYP Architecture & Engineering, Washington, D.C.


 

CSE: Have you specified distinctive HVAC systems on any high-performance campus projects?

Davallou: Yes, for all of the College of Marin projects including the main building; math and science buildings have geothermal HVAC systems.

CSE: What unique HVAC requirements do high-performance campus projects have that you wouldn't encounter in other projects?

Davallou: Geothermal systems will require a detailed well-test analysis and the water department's approval. For example, for the Mission College project's main building, we had to change the vertical-loop design to horizontal-loop during the construction administration because of leakage, which was not acceptable by the water department.

CSE: When retrofitting existing buildings for such projects, what challenges have you faced and how have you overcome them?

Davallou: We've seen space issues for thermal storage and geothermal. For Soka University, we looked at a void space near the central plant to locate the chilled-water thermal storage tanks.

 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me