High output accelerometer for machinery health monitoring

The 786-500-D2 accelerometer by Meggitt is designed for condition monitoring for rotating equipment and can be used in hazardous areas because of its Class I Div 2/Zone 2 certification.

01/25/2012


The 786-500-D2 accelerometer by Meggitt is designed for condition monitoring for rotating equipment and can be used in hazardous areas because of its Class I Div 2/Zone 2 certification. Courtesy: MeggittMeggitt's 786-500-D2 is a new high output accelerometer for machinery health monitoring. The 786-500-D2 accelerometer carries CSA approvals for Class I Div 2/Zone 2 areas and has a high 500 mV/g output sensitivity and a broadband frequency response for multi-use applications.

The 786-500-D2 accelerometer is well suited for condition monitoring of a variety of rotating equipment including those in hazardous areas. Slow speed applications, such as wind turbine generators will benefit from the strong 500 mV/g output of the 786-500-D2 because it overcomes data collector noise that can mask peaks at low frequencies. In high speed applications, such as machine tool spindles or gear mesh frequencies the sensor’s higher sensitivity results in better detection of low level vibrations.

The accelerometer houses a 500 mV/g sensing element with a tight 5% sensitivity tolerance coupled with a ± 3 dB frequency response range that covers 0.2 to 14,000 Hz. As a multi purpose sensor with a full scale acceleration range of 10 g and an excellent broadband noise floor of 250 μg, the 786-500-D2 is ideal for applications where both ends of the machine spectrum need to be monitored simultaneously.

Class I Div 2/Zone 2 certification means the 786-500-D2 can be used in higher risk areas, those defined as areas where hazardous gas, vapors or mist would only be present under abnormal conditions. While not as stringent as Division 1/Zone 1 certifications, this CSA certified unit can be safely used on motors, pumps, fans and other process equipment located in hazardous areas. Since no safety barriers are required in Division 2/Zone 2 areas, installation of the sensor is simplified.

Meggitt PLC

www.meggitt.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com

controleng.com/sensors



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me