High-efficiency UPS

The Liebert NXL 1100kVA/1100 kW UPS is from Emerson Network Power.

05/23/2012


Emerson Network Power has introduced the Liebert NXL 1100 kVA/1100 kW UPS to offer medium to large data centers a level of operating efficiency previously available only in transformer-free systems, but with the safety, fault tolerance, and reliability demonstrated by transformer-based systems. The Liebert NXL UPS is UL and CSA listed and is available globally for 60 Hz applications—480, 575, or 600 Vac. The Liebert NXL UPS is the first large transformer-based UPS system to be tested, UL listed, and labeled to UL1778 fourth edition specifications. The highest-capacity transformer-based UPS in the industry, Liebert NXL 1100 kVA/1100 kW UPS provides operating efficiency at typical load levels in double conversion mode with up to 98% efficiency when operating in Intelligent Eco-Mode. The Liebert NXL UPS battery ground fault isolation results in normal system operation even under battery ground fault conditions. During these fault conditions, the system does not go to bypass as happens with transformer-free technologies.

Emerson Network Power

www.emersonnetworkpower.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me