Heat pump control

Bosch's DDC Controller option for FHP heat pumps operates in 100% stand-alone control mode or connects to a BAS using open protocols like BACnet, Modbus, N2, or LonWorks.

05/02/2014


Bosch's DDC Controller option for FHP heat pumps operates in 100% stand-alone control mode or connects to a BAS using open protocols like BACnet, Modbus, N2, or LonWorks. Courtesy: BoschBosch's DDC Controller option for FHP heat pumps is preprogrammed and factory installed to be job site ready. The controller is installed with the unit's Unit Protection Module, which controls the heat pump's operations and monitors the safety controls that protect it. The DDC Controller operates in 100% stand-alone control mode or connects to a BAS using open protocols like BACnet, Modbus, N2, or LonWorks. It provides real-time information on zone temperatures, leaving air and water temperatures, and more, all of which can be monitored from a central control computer/laptop with unit fault indications displayed. To complement the controller, Bosch FHP offers a line of intelligent space sensors to provide precision measurement and communication capabilities. The DDC Controller offers more than 15 available input/outputs including discharge air temperature, leaving water temperature, alarm status, and heating and cooling setpoints.

Bosch

www.bosch.com 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me