Healthy Improvements for Aging Hospital

New regulations, mandates, environmental guidelines and increasing maintenance costs were putting a strain on an already tight budget for Methodist Healthcare-McNairy Hospital in rural Tennessee. "Our 30-year old physical plant was in need of major updating and replacement," says...

01/01/2001


New regulations, mandates, environmental guidelines and increasing maintenance costs were putting a strain on an already tight budget for Methodist Healthcare-McNairy Hospital in rural Tennessee.

"Our 30-year old physical plant was in need of major updating and replacement," says hospital administrator Rosemont Tyler. "The location of the hospital made it difficult for service companies to address our problems on a piecemeal basis. These issues, coupled with the magnitude of capital required for the project, made it necessary for us to explore alternative ways to get the job done."

The existing generator was old and improperly sized for the hospital's existing load, operating room comfort was a problem and much of the mechanical equipment was reaching the end of its useful life. The new equipment specified for the hospital included the following:

  • An emergency generator for protection from electrical outages.

 

  • A variable-air-volume (VAV) system to serve the operating rooms and X-ray areas. Converting electric VAV reheat to steam has resulted in utility savings.

 

  • A lighting retrofit to improve light levels and reduce costs.

 

  • Chillers with improved efficiency and reliability.

Finally, at the heart of the hospital's new infrastructure, a building-management system provides monitoring and control of critical areas in the hospital. As in most hospital retrofit projects, operations were maintained during the work.

For more information about PACT from Trane, circle 104 on the Reader Service Card on page 77.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me