Health care facility uses water wisely

Sustainable water management allows the Peter Doherty Institute for Infection and Immunity to save water and maintain lavish gardens.

03/22/2016


Figure 2: This shows the 10th-storey combined greywater-treatment reed bed and green roof, a double use of space. Courtesy: CJ Arms and AssociatesThe Peter Doherty Institute for Infection and Immunity in Melbourne, Australia, brings together the city's leading biomedical scientists and public health practitioners working in infection and immunology research. It features world-class laboratory facilities in conjunction with teaching and learning facilities and a number of sustainable water-management initiatives—including low-flow fixtures and fittings, and flow controls.

Toilet and urinal flushing in the building is provided by the roofwater collection system, which saves 264,000 gallons of water each year. The facility's passive greywater treatment system saves an additional 343,000 gallons of water annually. The greywater treatment system features a vertical-flow vegetated reed bed (see Figure 2) and also provides a lush, landscaped green roof that can be viewed from the 10th-storey executive boardroom.

This building was awarded a five-star Green Star building rating from the Green Building Council of Australia, and the greywater treatment system is the first in the world to combine vertical-flow greywater treatment with a green roof.


Peter Harbour is a senior scientist at CJ Arms and Associates.

 

Robyn Overall is water sustainability scientist at CJ Arms and Associates.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me