Ground testers for quick electrical equipment verification

Fluke's 1623-2 and 1625-2 Earth Ground Testers come are designed to speed verification of a reliable connection to earth for grounded electrical systems while lowering the risk of shock to users.

02/26/2014


Fluke's 1623-2 and 1625-2 Earth Ground Testers come are designed to speed verification of a reliable connection to earth for grounded electrical systems while lowering the risk of shock to users. Courtesy: FlukeFluke's 1623-2 and 1625-2 Earth Ground Testers come with features and accessories designed to speed verification of a reliable connection to earth for grounded electrical systems, helping solve power quality problems and lowering the risk of shock to users.

The Earth Ground Testers help engineers and electricians meet electrical codes, engineering standards, and local regulations to ensure that in the event of a lightning strike or utility overvoltage current will find a safe path to earth. They perform all four types of earth ground measurements: 3- and 4-pole fall-of-potential, 4-pole soil resistivity, selective testing, and stakeless testing.

The advanced testers feature USB connectivity for easy storage of up to 1,500 records with time stamp and fast measurement download, eliminating the need for manual data transfer.

Accessories include heavy-duty stakes that can be hammered into hard ground, color-coded wires to reduce errors, and a carry case. 

The 1625-2 model has additional features including automatic frequency control (AFC), which identifies existing interference and chooses a measurement frequency to provide more accurate values. It also has R* measurement, which calculates earth ground impedance with 55 Hz to more accurately reflect the resistance that a fault-to-earth ground would experience. 

Optional accessories include a 320 mm (12.7 in) split core transformer for performing selective testing on individual tower legs.

Fluke Corp.

www.fluke.com 

- Edited by CFE Media. See more Control Engineering energy and power products.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me