Ground fault protector

ABB’s F200 Ground Fault Equipment Protector (GFEP) is designed to protect equipment against damaging line-to-ground currents and can be applied to most electrical networks.

07/25/2013


ABB’s F200 Ground Fault Equipment Protector (GFEP) is designed to protect equipment against damaging line-to-ground currents and can be applied to most electrical networks. Courtesy: ABBABB’s F200 Ground Fault Equipment Protector (GFEP) is designed to protect equipment against damaging line-to-ground currents by disconnecting all ungrounded conductors of the faulted circuit. The ABB F200 GFEP line consists of the 2-pole F202 for single-phase networks and the 4-pole F204 for split phases, Delta, and Wye networks. The F200 GFEP detects ground faults by continuously measuring the current balance between live conductors and the neutral using a toroidal current transformer. F200 GFEP devices can be applied to most electrical networks up to 480Vac and can be installed in distribution panels and on critical equipment. They are suitable for a variety of industrial and commercial applications including: oil and gas, water and wastewater treatment, water pumps for fountains and irrigation, pharmaceutical manufacturing, semiconductor facilities, outdoor installations, and heating equipment 

ABB 

www.abb.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me