Giant (Lighting) Relay

San Francisco and its Moscone Center have been the host of a number of Lightfairs—the industry's top lighting exposition and conference. This year's show is on the other coast, but that's not stopping the convention center from making lighting news. With the recent opening of the Moscone West expansion, the convention center may boast one of the largest lighting control systems to date.

02/01/2005


San Francisco and its Moscone Center have been the host of a number of Lightfairs—the industry's top lighting exposition and conference. This year's show is on the other coast, but that's not stopping the convention center from making lighting news. With the recent opening of the Moscone West expansion, the convention center may boast one of the largest lighting control systems to date.

"With over 1,600 relay panels, this may be the largest lighting control system in the world," says Jon Stachelrodt, VP, Marketing for LC&D, Los Angeles, the manufacturer of the project's luminaire networking device.

According to Kristina Martin, Engineering Enterprise, Alameda, Calif., the project's electrical engineer and lighting designer, the job required so many panels because of the multi-function nature of the convention center's new 480,000-sq.-ft. space. The ground floor is open exhibition space, but the upper two floors are conference room swing spaces, according to Martin. "Each upper floor has the potential to be configured from one large meeting space into several dozen small conference rooms or any combination in between," she says.

This means each space requires two separate lighting systems: one for exhibitions and a separate, dimmable system to accommodate meetings. Engineering Enterprise selected a multi-lamp, recessed fluorescent fixture that uses eight compact fluorescent lamps with four two-lamp ballasts. Each dimmable incandescent luminaire, however, required a separate dimming control, meaning about 750 luminaires per swing space. Because of cost issues, the firm, instead, went with a stepped dimming process for the first three sets of lamps and a continuous dimming ballast for the last set of lamps in each fixture. The lamps were then custom-manufactured with the four-relay device in each of the 1,600 fixtures for superior control and, of course, significant wiring savings. "We calculated at one point that the wiring had been reduced by 97%!" says Stachelrodt.

For more on this project visit the Lighting community at www.csemag.com .





Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me