Provide island mode operational capability with two G3520C natural gas generator sets. The gensets are offered in 60- and 50-Hz versions that are driven by an electronically controlled, lean-burn gaseous-fueled reciprocating Caterpillar engine. The sets have an ISO electrical efficiency of 38.4% at 60 Hz and 40.

06/01/2008


Provide island mode operational capability with two G3520C natural gas generator sets. The gensets are offered in 60- and 50-Hz versions that are driven by an electronically controlled, lean-burn gaseous-fueled reciprocating Caterpillar engine. The sets have an ISO electrical efficiency of 38.4% at 60 Hz and 40.4% at 50 Hz. The sets operate at 60 Hz/1,800 rpm with a continuous rating of 2,055 ekW, or at 50 Hz/1,500 rpm with a continuous rating of 1,966 ekW. The sets have a standard NOx emissions rating of 1g/bhp-hr at 60 Hz and 500mg/NM3 at 50 Hz, with performance of 0.5 g/bhphr at 60 Hz and 250mg/NM3 at 50 Hz available through a 54 C separate circuit after-cooler system that can be used with a conventional cooling system arrangement.

Caterpillar Circle 454





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me